How can we improve the performance of acid and alkali resistant self priming pumps?
Article source: Faq Publication time:2024-05-20
How can we improve the performance of acid and alkali resistant self priming pumps? Don't worry, let me tell you all
1. The maximum circumferential velocity at the impeller outlet and the width of the impeller blade outlet of the acid and alkali resistant self suction pump can be increased by directly increasing the impeller speed by increasing the impeller. However, excessively increasing the maximum circumferential velocity at the impeller outlet and the width of the impeller blade outlet will alter the flow.
2. The relationship between water storage capacity and self suction performance: When the water storage capacity increases, the self suction height of the pump significantly increases, but when the water output is too large, it will slow down the gas discharge process, which will increase the self suction time. Therefore, when the self suction height requirement is high but the self suction time requirement is not too strict, the water storage capacity of the pump can be increased, that is, the volume of the storage chamber can be increased. However, when the self suction time requirement is strict, the size of the storage chamber should be reasonably determined.
3. The relationship between reflux hole area, self suction time, and self suction height: Within the critical reflux hole area, as the reflux hole area increases, the self suction time decreases, and the self suction height decreases accordingly. Therefore, when the self suction time requirement is strict and the self suction height requirement is not high, the area of the reflux hole can be appropriately increased. Conversely, the area of the reflux hole should be appropriately reduced.
4. The acid and alkali resistant self suction pump can be equipped with a gas-liquid separation acceleration device to accelerate gas-liquid separation, which can shorten the self suction time. The simplest gas-liquid separation acceleration device is to add a baffle in the gas-liquid separation chamber. Adding baffles in the gas-liquid separation chamber has almost no effect on the self suction height. So, as long as the structure allows, baffles should be installed in the gas-liquid separation chamber to accelerate gas-liquid separation and shorten the self suction time.