Common faults and treatment methods of acid and alkali resistant self suction pumps
Article source: Faq Publication time:2024-05-20
1、 What are the reasons and treatment methods for the high noise of acid and alkali resistant self suction pumps?
1. Motor reversal. (The first element is to adjust the motor wiring to forward rotation)
2. Impeller friction or suction of foreign objects, sealing and vibration during friction. (Open the main body and check if the impeller is damaged. Solution: Clean the foreign objects inside the impeller or replace it.)
3. The sound of drawing water is loud when entering the air. (Check the inlet and outlet pipelines and joints, as well as the sealing position of the pump inlet for the possibility of air intake. If found, repair it in a timely manner.)
4. The bearing is damaged and the sound is harsh. (Replace with new motor bearings)
5. The axis is eccentric, and when rotating, the contact surface of the shaft seal rubs and swings left and right. (Disassemble and recalibrate the axis)
2、 The causes and solutions of water leakage in the mechanical seal of acid and alkali resistant self suction pumps?
1. The shaft seal is burnt out. (Replace the shaft seal with a new one and inspect the pipeline to identify the cause of the burning.)
2. The fixed ring is broken, the shaft seal cover, the rotating ring is broken, and the expansion ring is broken. (Check for hard or sharp impurities inside and replace the broken part)
3. The impeller lock cap is not locked or sealed properly. (Replace the impeller lock cap and sealing ring, and tighten them)
4. A certain part is corroded. (Replace with better components or accessories made of materials suitable for the potion)
5. The axis height is too high during installation, or the expansion ring is not pressed to the bottom. (Disassemble and readjust the shaft height. Ensure that the expansion ring is not pressed to the bottom during installation)
6. The motor spindle is separated from the shaft center, and the impeller rises. (Re fix the axis to ensure that the hex screws are not locked.)
3、 What are the main factors causing water leakage, pump body deformation, and cracking in acid and alkali resistant self priming pumps? (Note: The mechanical seal is intact, but there is water seepage phenomenon)?
1. The liquid temperature is too high.
2. Long term high pressure state.
3. During installation, if the screw lock is too tight, it will expand and burst as it gets hotter.
4. The material of the pump body is not suitable for use in this liquid.
5. Long service life and aging.